Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Rev. cuba. oftalmol ; 35(1): e1477, ene.-mar. 2022. graf
Article in Spanish | LILACS, CUMED | ID: biblio-1409036

ABSTRACT

La exotropía sensorial se define como una desviación ocular divergente unilateral o bilateral, dada por anomalías oculares congénitas o adquiridas; es más frecuente en adultos. El objetivo de la cirugía de estrabismo en el adulto es restablecer la visión binocular, reduciendo la diplopía y al lograr el alineamiento ocular, mejorar su estética, por lo que antes de realizar la cirugía se debe tratar la causa que provoca la baja visión. El procedimiento quirúrgico de elección es la cirugía monocular, pero si la desviación es grande se realizará cirugía binocular. Se presenta una paciente femenino de 25 años de edad portadora de lentes de contacto por miopía elevada del ojo derecho (9,00 -0.75 x 105º con 0,2 de agudeza visual mejor corregida), exotropía de más de 25º por Hirschberg, limitación de aducción del ojo derecho y por método de oclusor y prismas a 6 metros sin cristales y con sus lentes de contacto, ambos ojos 50 ∆ b interna, no estereopsia y suprime ojo derecho. Por todas las ventajas que presenta la cirugía monocular, se decidió realizarla en el ojo derecho, se colocó anestesia local peribulbar, se realizó recesión amplia del recto lateral a 12 mm y se realizó 8 mm de resección del recto medial; en el postoperatorio se logró 10 ∆ b interna y por momentos ortotropia; refirió diplopía post quirúrgica que resolvió espontáneamente. Los resultados quirúrgicos en la exotropía sensorial son menos alentadores ya que con el tiempo pueden evolucionar hacia la hipercorrección o hacia la recurrencia(AU)


Sensory exotropía is defined as a unilateral or bilateral divergent ocular deviation, given by congenital or acquired ocular anomalies, and is more frequent in adults. The objective of the strabismus surgery in adults is to reestablish binocular vision, reduce diplopía, improve ocular alignment and enhance quality of life; before performing surgery the cause of low vision should be treated. The preferred surgical procedure is a monocular approach, but if there is a large deviation a binocular procedure should be performed. The case presented Is a 25 year-old female with high myopia of the right eye (-9.00 -0.75 x 105º with 0.2 of best corrected visual acuity), exotropía of more than 25º for Hirschberg, limitation of aducción of the right eye and with both the oclusor method and prisms to 6 meters without glasses and with her contact lenses, both eyes have 50∆ of internal base, no estereopsia and suppression of the right eye. For its advantages a monocular approach (of the right eye) was preferred, with peribulbar anesthesia: recession to 12mm of the lateral rectus combined with 8 mm of resection of the medial rectus; in the postoperative she presented a 10∆ intern base deviation and for moments ortotropia; she referred diplopia that solved spontaneously. The surgical results in sensory exotropía are less encouraging since they have higher hypercorrection and recurrence rates(AU)


Subject(s)
Humans , Female , Adult , Surgical Procedures, Operative , Exotropia/etiology , Eye Abnormalities , Strabismus/surgery , Quality of Life , Recurrence
2.
Rev. cuba. oftalmol ; 35(1): e1192, ene.-mar. 2022.
Article in Spanish | LILACS, CUMED | ID: biblio-1409027

ABSTRACT

La masificación del Internet y comunicación móvil, así como el mayor acceso a herramientas digitales y de dispositivos electrónicos ha modificado la calidad de vida y salud de la población mundial, con un impacto especialmente importante en los niños. El uso desmedido de pantallas constituye un problema en esta población por su impacto en el sedentarismo, sobrepeso, alteraciones en el comportamiento, trastornos depresivos y del sueño, pero también por el efecto que tiene sobre el sistema visual en desarrollo: predispone a síndrome de ojo seco, a un exceso de acomodación-convergencia, provoca un desenfoque hipermetrópico de la fóvea (se cree que esto estimula el crecimiento axial), aumenta la tensión del cuerpo ciliar y músculos extraoculares, además de los efectos nocivos de la luz azul-violeta para las estructuras intraoculares. Estudios sugieren que los niños son más propensos a desarrollar miopía por estar menos expuestos a la luz natural y pasar más tiempo en ambientes cerrados ante pantallas, muchos incluso han demostrado una asociación entre el uso de pantallas, el trabajo cercano y la presencia de miopía, pero no existen datos concluyentes que aíslen un riesgo independiente. A partir de esta revisión se concluye que la prevalencia de la miopía está aumentando con base en una etiología multifactorial(AU)


The massification of the Internet and mobile communication, as well as increased access to digital tools and electronic devices, have changed the quality of life and health of the world's population, with a particularly important impact on children. The excessive use of screens is a problem among this population because of its impact on sedentary lifestyles, overweight, behavioral alterations, depressive and sleep disorders; but also because of its effect on the developing visual system, since it predisposes to dry eye syndrome, excessive accommodation-convergence, causes hypermetropic defocus at the fovea (this is believed to stimulate axial growth), increases the tension of the ciliary body and extraocular muscles, in addition to the harmful effects of blue-violet light on intraocular structures. Studies suggest that children are more prone to developing myopia because they are less exposed to natural light and spend more time in indoor environments in front of screens; many studies have even shown an association between the use of screens, close-eye work and the presence of myopia, but there are no conclusive data that isolate an independent risk. From this review, the prevalence of myopia is concluded to be increasing based on a multifactorial etiology(AU)


Subject(s)
Humans , Quality of Life , Internet , Electronics , Myopia/etiology , Sleep Wake Disorders , Dry Eye Syndromes , Life Style
3.
In. Hernández Silva, Juan Raúl. Facoemulsificación. La Habana, Editorial Ciencias Médicas, 2022. , ilus.
Monography in Spanish | CUMED | ID: cum-78482
4.
Rev. cuba. oftalmol ; 34(3): e1044, 2021. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1352022

ABSTRACT

Objetivo: Evaluar la asociación entre los factores de riesgo en pacientes miopes en edad pediátrica. Métodos: Se realizó un estudio con diseño de casos y control para evaluar los factores de riesgo asociados a la miopía en los pacientes atendidos en la consulta del Servicio de Oftalmología Pediátrica del Instituto Cubano de Oftalmología "Ramón Pando Ferrer". La muestra estuvo conformada por 263 pacientes (123 casos y 140 controles) que cumplieron los criterios de inclusión y de exclusión. Las variables del estudio fueron la edad, el sexo, el color de la piel, la zona de procedencia, el bajo peso al nacer, la prematuridad, las madres fumadoras, el antecedente de familiares con defectos refractivos, las horas de exposición a las pantallas, las horas de exposición a la luz solar y la longitud axial. Resultados: Se encontró correlación entre el antecedente de familiares con defecto refractivo y la presencia de miopía (p = 0,009), y a su vez un riesgo de 1,9 de padecerla; más de 2 horas - pantallas se relaciona con pacientes miopes (p = 0,003) y duplica el riesgo. Más de 2 horas de luz solar fue más frecuente en los controles (p = 0,004) y es un factor de protección; las longitudes axiales fueron mayores en miopes (p = 0,000) y se correlacionó la exposición horas - pantallas con una mayor longitud axial. Conclusiones: Los antecedentes familiares de defectos refractivos aumentan 1,9 veces el riesgo de padecer miopía; la exposición a las pantallas por más de 2 horas al día lo duplica y la exposición a la luz solar por el mismo tiempo lo reduce a la mitad. La longitud axial es mayor en miopes y en los expuestos a las pantallas(AU)


Objective: Evaluate the association between risk factors in pediatric myopic patients. Methods: A case-control study was conducted to evaluate the risk factors associated to myopia in patients attending the Pediatric Ophthalmology Service at Ramón Pando Ferrer Cuban Institute of Ophthalmology. The sample was 263 patients (123 cases and 140 controls) who met the inclusion criteria. The study variables were age, sex, skin color, place of residence, low birth weight, prematurity, smoking mothers, a family history of refractive defects, screen time, sun exposure hours and axial length. Results: A correlation was found between a family history of refractive defects and the presence of myopia (p = 0.009), as well as a 1.9 risk of developing the disorder. More than two screen hours were associated to myopic patients (p = 0.003), doubling the risk. More than two sun exposure hours were more frequent among controls (p = 0.004) and constitute a protection factor. Axial lengths were greater among myopics (p = 0.000). Exposure and screen time were correlated with greater axial length. Conclusions: A family history of refractive defects increases the risk for myopia 1.9 times, exposure to screens for more than two hours per day doubles it, and the same number of sun exposure hours reduces it to half. Axial length is greater among myopics and screen exposed people(AU)


Subject(s)
Humans , Child , Adolescent , Infant, Low Birth Weight , Risk Factors , Myopia/etiology , Case-Control Studies , Screen Time
5.
Rev. cuba. oftalmol ; 32(4): e756, oct.-dic. 2019. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1099102

ABSTRACT

RESUMEN El síndrome de párpado laxo es un cuadro que con frecuencia pasa inadvertido. Los síntomas que lo caracterizan son generalmente muy inespecíficos, por lo que a menudo los pacientes son diagnosticados erróneamente con conjuntivitis infecciosa crónica, blefaritis o síndrome del ojo seco, lo que puede llevar a un retraso o falta de tratamiento durante meses o incluso años. Se presenta el caso de una paciente de 54 años, atendida en el Servicio de Cirugía Plástica Ocular del Instituto Cubano de Oftalmología "Ramón Pando Ferrer", quien refirió sensación de arenilla, ardor y secreciones. Durante el interrogatorio se constató la presencia de trastornos del sueño y eversión del párpado superior al dormir. Se le diagnosticó un síndrome de párpado laxo y se decidió realizar tratamiento quirúrgico, con el uso de la técnica de acortamiento horizontal del párpado. Al mes de la cirugía se observó la desaparición de toda la sintomatología y un resultado estético muy favorable. Aunque el síndrome del párpado laxo no es potencialmente mortal, puede conducir a condiciones serias que amenazan la visión y ser un indicador de condiciones sistémicas fatales(AU)


ABSTRACT The lax eyelid syndrome is a condition that often goes unnoticed. The symptoms that characterize it are generally very nonspecific, so patients are often misdiagnosed with chronic infectious conjunctivitis, blepharitis, or dry eye syndrome, which can lead to a delay or lack of treatment for months or even years. The case of a 54-year-old patient is presented. The patient was treated at the Ocular Plastic Surgery Service of Ramón Pando Ferrer Cuban Institute of Ophthalmology and reported gritty sensation, burning and secretions. During the interrogation, the presence of sleep disorders and dislocation of the upper eyelid during sleep was found. The patient was diagnosed with lax eyelid syndrome and it was decided to perform surgical treatment, using the horizontal lid shortening technique. One month after the surgery, the disappearance of all the symptoms and a very favorable aesthetic result were observed. Although lax eyelid syndrome is not life-threatening, it can lead to serious conditions that threaten vision and can be an indicator of fatal systemic conditions(AU)

6.
Rev. cuba. oftalmol ; 32(3): e797, jul.-set. 2019. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1099084

ABSTRACT

RESUMEN Objetivo: Identificar las características de los pacientes pediátricos con miopías por encima de 6 dioptrías. Métodos: Se realizó un estudio descriptivo y observacional, de corte longitudinal, en 43 niños entre 3 y 15 años de edad con diagnóstico de miopía igual o mayor de 6 dioptrías en uno o ambos ojos (72 ojos), quienes acudieron a la consulta del Servicio de Oftalmología Pediátrica y Estrabismo del Instituto Cubano de Oftalmología "Ramón Pando Ferrer" durante el periodo comprendido entre enero y diciembre del año 2018. Las variables del estudio fueron la edad, el sexo, el color de la piel, la miopía (isometrópica y anisometrópica), la longitud axial, la agudeza visual con corrección, el tipo de corrección óptica, la presencia y el grado de estereopsia. Resultados: Predominó el grupo de 3 a 5 años (34,4 por ciento), el sexo femenino y el color de la piel blanca. La longitud axial aumentó junto con el equivalente esférico de los pacientes. La corrección más usada correspondió a los cristales, aunque se demostró estadísticamente que con los lentes de gas permeables los pacientes presentaban mejor agudeza visual (p= 0,016), donde se registró también la media más alta de equivalente esférico. De 43 pacientes, 20 (46,5 por ciento) no presentaron estereopsia. Los pacientes con anisometropías (64 por ciento) no presentaron estereopsia, lo que fue estadísticamente significativo. Conclusiones: Con los lentes de gas permeables los pacientes presentan mejor agudeza visual y mayor equivalente esférico. La mayor cantidad de pacientes sin estereopsia corresponde a las miopías por anisometropías(AU)


ABSTRACT Objective: Identify the characteristics of pediatric patients with greater than 6 diopter myopia. Methods: An observational descriptive longitudinal study was conducted of 43 children aged 3-15 years diagnosed with myopia equal to or greater than 6 diopters in one or both eyes (72 eyes) who attended the Pediatric Ophthalmology and Strabismus Service at Ramón Pando Ferrer Cuban Institute of Ophthalmology from January to December 2018. The variables considered were age, sex, skin color, myopia (isometropic or anisometropic), axial length, corrected visual acuity, type of optical correction, and presence and degree of stereopsis. Results: A predominance was found of the 3-5 years age group (34.4 percent), female sex and white skin color. Axial length increased with spherical equivalent. The most common correction was glasses, but it was statistically demonstrated that gas permeable lenses provided better visual acuity (p= 0.016) and the highest spherical equivalent mean. Of the 43 patients evaluated, 20 (46.5 percent) did not present stereopsis. Patients with anisometropia (64 percent) did not present stereopsis, which constituted a statistically significant fact. Conclusion: Gas permeable lenses provide better visual acuity and a greater spherical equivalent. Most of the patients without stereopsis have anisometropic myopia(AU)


Subject(s)
Humans , Female , Child, Preschool , Child , Contact Lenses/adverse effects , Myopia/diagnosis , Myopia/epidemiology , Epidemiology, Descriptive , Longitudinal Studies , Observational Study
7.
Cir Cir ; 86(1): 44-49, 2019.
Article in English | MEDLINE | ID: mdl-30951042

ABSTRACT

BACKGROUND: Corneal pachymetry is widely used for refractive surgery and follow up in keratoconus, accurate measurement is essential for a safe surgery. OBJECTIVE: To assess intraobserver reliability of central corneal thickness (CCT) measurements using optical low-coherence reflectometry (OLCR) technology and its agreement with ultrasonic pachymeter (US). METHOD: Randomized and prospective comparative evaluation of diagnostic technology. One randomly healthy eye of subjects was scanned three times with both devices. Intraobserver within-subject standard deviation (Sw), coefficient of variation (CVw) and intraclass correlation coefficient (ICC) were obtained for reliability analysis; for study agreement, data were analyzed using the paired-sample t test and the Bland-Altman LoA method. The mean of three scans of each equipment was used to assess the LoA. RESULTS: The study enrolled 30 eyes of 30 subjects with average age of 28.70 ± 8.06 years. For repeatability, the Sw were 3.41 and 5.96 µ, the intraobserver CVw was 2 and 4% and ICC 0.991 and 0.988, for OLCR and US respectively. The mean CCT difference between OLCR and US was 8.90 ± 9.03 µ (95% confidence interval: 5.52-2.27 µ), and the LoA was 35.40 µ. CONCLUSIONS: OLCR technology provided reliable intraobserver CCT measurements. Both pachymetry measurements may be used interchangeably with minimum calibration adjustment.


ANTECEDENTES: La paquimetría corneal es ampliamente utilizada para la cirugía refractiva y el seguimiento de pacientes con queratocono. La medición exacta es esencial para una cirugía refractiva segura. OBJETIVO: Evaluar la reproducibilidad intraobservador en la medición del grosor corneal central (GCC) utilizando reflectometría óptica de baja coherencia (OLCR) y su concordancia con la paquimetría ultrasónica. MÉTODO: Estudio prospectivo, comparativo y aleatorizado de una tecnología diagnóstica. Se midió de forma aleatorizada un ojo de cada sujeto en tres ocasiones con ambos equipos. Para el análisis de fiabilidad se obtuvieron la desviación estándar (DE) intrasujeto, el coeficiente de variación (CV) y el coeficiente de correlación intraclase (CCI). Para el estudio de concordancia se analizaron los datos usando una prueba t pareada simple, además de los límites de acuerdo de Bland-Altman (LA). Para la evaluación de los LA se utilizó el promedio de las tres mediciones de cada equipo. RESULTADOS: El estudio incluyó 30 ojos de 30 sujetos con una edad promedio de 28.70 ± 8.06 años. Para la repetibilidad, la DE intrasujeto fue de 3.41 y 5.96µ, el CV del 2 y el 4%, y el CCI de 0.991 y 0.988, para el OLCR y el paquímetro ultrasónico, respectivamente. La diferencia del GCC promedio entre el OLCR y el paquímetro ultrasónico fue de 8.90 ± 9.03µ (intervalo de confianza del 95%: 5.52-2.27µ), y el LA fue de 35.40µ. CONCLUSIONES: La tecnología de OLCR proporciona medidas del GCC intraobservador fiables. Ambas mediciones paquimétricas pueden usarse de forma intercambiable con mínimos ajustes de calibración.


Subject(s)
Cornea/diagnostic imaging , Corneal Pachymetry/methods , Tomography, Optical Coherence , Adult , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Ultrasonography , Young Adult
8.
Cir Cir ; 86(1): 50-55, 2018.
Article in Spanish | MEDLINE | ID: mdl-29681640

ABSTRACT

Background: Corneal pachymetry is widely used for refractive surgery and follow up in keratoconus, accurate measurement is essential for a safe surgery. Objective: To assess intraobserver reliability of central corneal thickness (CCT) measurements using optical low-coherence reflectometry (OLCR) technology and its agreement with ultrasonic pachymeter (US). Method: Randomized and prospective comparative evaluation of diagnostic technology. One randomly healthy eye of subjects was scanned three times with both devices. Intraobserver within-subject standard deviation (Sw), coefficient of variation (CVw) and intraclass correlation coefficient (ICC) were obtained for reliability analysis; for study agreement, data were analyzed using the paired-sample t test and the Bland-Altman LoA method. The mean of three scans of each equipment was used to assess the LoA. Results: The study enrolled 30 eyes of 30 subjects with average age of 28.70 ± 8.06 years. For repeatability, the Sw were 3.41 and 5.96 µ, the intraobserver CVw was 2 and 4% and ICC 0.991 and 0.988, for OLCR and US respectively. The mean CCT difference between OLCR and US was 8.90 ± 9.03 µ (95% confidence interval: 5.52-2.27 µ), and the LoA was 35.40 µ. Conclusions: OLCR technology provided reliable intraobserver CCT measurements. Both pachymetry measurements may be used interchangeably with minimum calibration adjustment.


Antecedentes: La paquimetría corneal es ampliamente utilizada para la cirugía refractiva y el seguimiento de pacientes con queratocono. La medición exacta es esencial para una cirugía refractiva segura. Objetivo: Evaluar la reproducibilidad intraobservador en la medición del grosor corneal central (GCC) utilizando reflectometría óptica de baja coherencia (OLCR) y su concordancia con la paquimetría ultrasónica. Método: Estudio prospectivo, comparativo y aleatorizado de una tecnología diagnóstica. Se midió de forma aleatorizada un ojo de cada sujeto en tres ocasiones con ambos equipos. Para el análisis de fiabilidad se obtuvieron la desviación estándar (DE) intrasujeto, el coeficiente de variación (CV) y el coeficiente de correlación intraclase (CCI). Para el estudio de concordancia se analizaron los datos usando una prueba t pareada simple, además de los límites de acuerdo de Bland-Altman (LA). Para la evaluación de los LA se utilizó el promedio de las tres mediciones de cada equipo. Resultados: El estudio incluyó 30 ojos de 30 sujetos con una edad promedio de 28.70 ± 8.06 años. Para la repetibilidad, la DE intrasujeto fue de 3.41 y 5.96 µ, el CV del 2 y el 4%, y el CCI de 0.991 y 0.988, para el OLCR y el paquímetro ultrasónico, respectivamente. La diferencia del GCC promedio entre el OLCR y el paquímetro ultrasónico fue de 8.90 ± 9.03 µ (intervalo de confianza del 95%: 5.52-2.27 µ), y el LA fue de 35.40 µ. Conclusiones: La tecnología de OLCR proporciona medidas del GCC intraobservador fiables. Ambas mediciones paquimétricas pueden usarse de forma intercambiable con mínimos ajustes de calibración.


Subject(s)
Cornea/anatomy & histology , Corneal Pachymetry/methods , Tomography, Optical Coherence/methods , Ultrasonography/methods , Adult , Cornea/diagnostic imaging , Corneal Pachymetry/instrumentation , Female , Humans , Male , Middle Aged , Observer Variation , Pilot Projects , Prospective Studies , Reproducibility of Results , Ultrasonography/instrumentation , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...